Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
3120-N323-P7T1-W14FR2-15A
E-T-A
1:
$40.52
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-23P7T1W14FR215A
E-T-A
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
3120-N
Thermal Circuit Breakers
Overcurrent Protection
15 A
240 VAC
24 VDC
2 Pole
Rocker
- 30 C
+ 60 C
Illuminated
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
3120-N323-P7T1-W14FR3-14A
E-T-A
1:
$44.27
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-23P7T1W14FR314A
E-T-A
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
3120-N
Thermal Circuit Breakers
Overcurrent Protection
14 A
115 VAC
50 VDC
2 Pole
Rocker
- 30 C
+ 60 C
Illuminated
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
3120-N323-P7T1-W19FG4-1.5A
E-T-A
1:
$57.63
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-23P7T1W19FG41.5A
E-T-A
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3120-N
Thermal Circuit Breakers
Overcurrent Protection
1.5 A
230 VAC
50 VDC
2 Pole
Rocker
- 30 C
+ 60 C
Illuminated
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
3120-N323-P7T1-W19FG4-15A
E-T-A
1:
$44.27
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-23P7T1W19FG415A
E-T-A
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3120-N
Thermal Circuit Breakers
Overcurrent Protection
15 A
230 VAC
50 VDC
2 Pole
Rocker
- 30 C
+ 60 C
Illuminated
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
3120-N303-N7Q1-M01H-16A
E-T-A
1:
$30.73
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-303N7Q1M01H16A
E-T-A
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
3120-N
Thermal Circuit Breakers
Overcurrent Protection
16 A
240 VAC
50 VDC
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-H7T1-W01Q-2A
E-T-A
1:
$37.65
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110H7T1W01Q2A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
2 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-H7T1-W01Q-5A
E-T-A
1:
$32.09
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110H7T1W01Q5A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
5 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-H7T1-W01Q-6A
E-T-A
1:
$32.08
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110H7T1W01Q6A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
6 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W01Q-5A
E-T-A
1:
$40.95
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W01Q5A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Circuit Breakers
Thermal
5 A
240 VAC, 415 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W01Q-7A
E-T-A
1:
$29.36
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W01Q7A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
7 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W02Q-2A
E-T-A
1:
$27.71
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W02Q2A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
2 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W02Q-3A
E-T-A
1:
$30.21
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W02Q3A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
3 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W02Q-4A
E-T-A
1:
$30.22
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W02Q4A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
4 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W02Q-5A
E-T-A
1:
$30.21
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W02Q5A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
5 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W02Q-6A
E-T-A
1:
$30.22
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W02Q6A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
6 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W04Q-1A
E-T-A
1:
$34.16
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W04Q1A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
1 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W04Q-2A
E-T-A
1:
$34.16
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W04Q2A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
2 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W04Q-3A
E-T-A
1:
$30.21
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W04Q3A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
3 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F110-P7T1-W04Q-8A
E-T-A
1:
$30.22
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F110P7T1W04Q8A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
8 A
240 VAC
50 VDC
1 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F120-H7T1-W01Q-3A
E-T-A
1:
$51.78
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F120H7T1W01Q3A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
3 A
415 VAC
50 VDC
2 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F120-P7T1-W01Q-1A
E-T-A
1:
$56.78
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F120P7T1W01Q1A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Circuit Breakers
Thermal
1 A
240 VAC, 415 VAC
50 VDC
2 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F120-P7T1-W01Q-2A
E-T-A
1:
$56.78
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F120P7T1W01Q2A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
2 A
415 VAC
50 VDC
2 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F120-P7T1-W01Q-4A
E-T-A
1:
$50.66
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F120P7T1W01Q4A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
4 A
415 VAC
50 VDC
2 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F120-P7T1-W01Q-5A
E-T-A
1:
$50.65
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F120P7T1W01Q5A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
5 A
415 VAC
50 VDC
2 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
3130-F120-P7T1-W01Q-6A
E-T-A
1:
$50.66
Non-Stocked Lead-Time 6 Weeks
Mouser Part No
457-30F120P7T1W01Q6A
E-T-A
Circuit Breakers Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double
Non-Stocked Lead-Time 6 Weeks
Buy
Min.: 1
Mult.: 1
Details
3130-F
Thermal Overcurrent
6 A
415 VAC
50 VDC
2 Pole
Rocker
- 30 C
+ 60 C
Non-Illuminated